一、准备
1.iDRAC开启SNMP服务
2. 确保开启snmp 和端口(116)
zabbix 服务端通过snmp验证
snmpget -v 2c -c xkeshi ip .1.3.6.1.4.1.674.10892.2.1.1.2.0
SNMPv2-SMI::enterprises.674.10892.2.1.1.2.0 = STRING: "iDRAC8"
二、zabbix web配置
1、创建值映射
zabbix web界面 —> 管理 —> 一般 —> 值映射
将根据下列名称进行值映射
DellDracDiskState
1 -> Unknown
2 -> Ready
3 -> Online
4 -> Foreign
5 -> Offline
6 -> Blocked
7 -> Failed
8 -> Non-RAID
9 -> RemovedDell iDRAC Network Device Connection Status
1 -> Connected
2 -> DisconnectedDell Open Manage System Status
1 -> Other
2 -> Unknown
3 -> OK
4 -> NonCritical
5 -> Critical
6 -> NonRecoverableDellPowerState
1 -> Other
2 -> Unknown
3 -> Off
4 -> OnDell PSU State Settings
1 -> Unknown
2 -> Online (state disabled)
4 -> not Ready
8 -> Fan Failure
10 -> Online and Fan Failure
16 -> On
242 -> Online and OKDellRaidLevel
1 -> Unknown
2 -> RAID-0
3 -> RAID-1
4 -> RAID-5
5 -> RAID-6
6 -> RAID-10
7 -> RAID-50
8 -> RAID-60
9 -> Concatenated RAID 1
10 -> Concatenated RAID 5DellRaidVolumeState
1 -> Unknown
2 -> Online
3 -> Failed
4 -> DegradedDell_PSU_SensorState
1 -> Presence Detected
2 -> PS Failure
4 -> Predictuve Failure
8 -> PS AC lost
16 -> AC lost or out of range
32 -> AC out of range but still present
2、配置全局变量{$SNMP_COMMUNITY_IDRAC}
zabbix web界面 —> 管理 —> 一般 —> 宏
3、导入模板
模板下载地址:github./endersonmaia/zabbix-templates/tree/master/dell/idrac
zabbix web界面 —> 配置 —> 模板 —> 导入
Template_Dell_iDRAC_SNMPv2.zbx.xml
4、创建主机
zabbix web界面 —> 配置 —> 主机 —> 创建主机
输入主机地址及SNMP地址和端口,保存
5、利用grafana进行可视化配置
至此,所有操作步骤已经完成,你可以定义不同的图形将所有的监控项进行整合,
更多推荐
风扇,温度,内存,模板,zabbix
发布评论